Online Neutron Moisture Analyzer can be used in industrial production process for online continuous detection of material moisture, which is widely suitable for such industries as iron and steel, building material, cement, casting, glass, ceramics, etc., and can output control signals to realize close loop automatic control in the production process. To adapt to the requirements of different fields and different processes, the product is classified into transmission type online neutron moisture analyzer, reflection type online neutron moisture analyzer and reflection type belt neutron moisture analyzer.
The neutron source is controlled by a switch with high safety, being convenient for servicing and safe.
The detection is not influenced by such factors as dust, water vapor, material electrical conductivity, particle size, etc.
By adopting the new-type neutron automatic peak stabilizing technology for energy spectrum researched and developed by the company, it can ensure that the long-term drift of the instrument is less than 0.1%.
The non-contact detection mode in which the probe and material has no contact can ensure long-term use.
There is a unique alarm device with a dual fail-safe function.
Main performance indexes:
Measured material type: Sinter mixture
² Measurement mode: DF-5740 Transmission Type Online Neutron Moisture Analyzer can be selected and used. DF-5744 Reflection Type Online Belt Moisture Analyzer can also be selected and used.
² Measurement range: 0%~10%.
² Measurement accuracy: ±0.4%.
² The long-term stability of ray counting rate (>8 hours) and the repeatability of measurement value<0.1%
² Host working environment: 0°C - +50°C, relative humidity≤95%
² Probe working environment: -20°C - +50°C, relative humidity≤95%
² Radiation safety performance: The equivalent dose rate at 1m from the radioactive source<2.5μSv/h, meeting the dose standard for a non-radioactive workplace as regulated by the State. Working beyond 1m for a long time has no influence on human health.
Measured material type: Coke
² Measurement mode: DF-5741 Reflection Type Online Neutron Moisture Analyzer can be selected and used. DF-5744 Reflection Type Online Belt Moisture Analyzer can also be selected and used.
² Measurement range: 0%~20%.
² Measurement accuracy: When the coke moisture changes from 0% to 5%, the standard detection accuracy of the neutron moisture analyzer is ±0.5%.
When the coke moisture changes from 0% to 7%, the standard detection accuracy of the neutron moisture analyzer is ±0.8%.
When the coke moisture changes from 0% to 10%, the standard detection accuracy of the neutron moisture analyzer is ±1%~±1.2%.
² The long-term stability of ray counting rate (>8 hours) and the repeatability of measurement value<0.1%.
² Host working environment: 0°C - +50°C, relative humidity≤95%.
² Probe working environment: -20°C - +50°C, relative humidity≤95%
² Radiation safety performance: The equivalent dose rate at 1m from the radioactive source<2.5μSv/h, meeting the dose standard for a non-radioactive workplace as regulated by the State. Working beyond 1m for a long time has no influence on human health.